Temperature probes (Andivi ANDKBTF) are passive temperature cable sensors designed to measure the temperature of various liquids, gases, internal temperature of objects, etc. Temperature probes are often applied to measure the temperature of liquids in air-conditioning, heating and cooling (AHU) products – such as: boilers, feeders, pipelines, ducts, storage tanks, storage vessels; and also in products and semi-finished products in industry and automation.
With the appropriate sensor elements (thermocouples), they can be connected to all common control and remote monitoring systems.
In addition to the passive version of the temperature probe, temperature probes are also available in an active version with 0-10V or 4-20mA output and in a Modbus version.
Additional options for the ANDKBTF sensor:
- 2-conductor cable (standard); 2m length (standard),
- 3-wire cable,
- 4-wire cable,
- additional cable lengths available depending on need
- the many variations of the temperature probe are presented below
Temperature probe cable according to maximum measurement temperature
Product number: ANDKBTF
Technical specifications – Cable Temperature Sensor
Maximum temperatures depending on cable material and thermocouple version in the temperature probe – table below:
Image | Cable material | Temp. | Thermocouples available |
![]() | PVC Cable | up to 105°C | PT100, PT100 1/3DIN, PT 1000, PT1000 1/3DIN, NI1000, NI1000TK5000, NTC 5k / 10k / 20k / Precon / KTY81-210, NTC 1,8 kOhm, LM235Z, DS18B20 |
![]() | Silicone cable | up to180°C | PT100, PT100 1/3DIN, PT 1000, PT1000 1/3DIN, NI1000, NI1000TK5000, NTC 5k / 10k / 20k / Precon / KTY81-210, NTC 1,8 kOhm, LM235Z, DS18B20 |
![]() | High-temperature silicone cable | up to 260°C | PT100, PT100 1/3DIN, PT 1000, PT1000 1/3DIN, NI1000, NI1000TK5000, NTC 5k / 10k / 20k / Precon / KTY81-210, NTC 1,8 kOhm, LM235Z, DS18B20 |
![]() | Glass wool cable | up to 400°C | PT100, PT100 1/3DIN, PT 1000, PT1000 1/3DIN, NI1000, NI1000TK5000, NTC 5k / 10k / 20k / Precon / KTY81-210, NTC 1,8 kOhm, LM235Z, DS18B20 |
The temperature probe is double rolled as standard for PVC and silicone conductors. The probe for glass silk conductors shall be hexagonal cross-linked. Note: The probe with glass wool connection cable cannot be made with WPC.
Variants of cable temperature sensors
Overview of the different probe thermocouples:
Overview of possible thicknesses or different diameters of the temperature probe:

Ø 3 mm
Ø 4 mm
Ø 5 mm
Ø 6 mm (standard)
from Ø 6 mm narrowed to Ø 3 mm
Overview of possible temperature probe lengths:

30 mm
40 mm
50 mm
60 mm
100 mm
150 mm
200 mm
400 mm
300 mm
500 mm
Overview of available thermocouples:
PT100 Class B
PT100 Class B
PT100 Class A
PT1000 Class A
PT100 1/3 DIN
PT1000 1/3 DIN
PT1000 1/10 DIN
PT 500
PT2000
NTC 1kOhm
NTC 1.8kOmh
NTC 5kOhm
NTC 10 kOhm
NTC 20 kOhm
NTC 100 kOhm
Ni1000
Ni1000TK5000
Ni500
KTY81-110
KTY81-120
KTY81-121
KTY81-122
KTY81-210
Dallas DS18B20
LM235Z
For PTC and NTC sensors, we have summarized the scaling of the temperature according to the electrical resistance on electrical resistance, as well as the temperature and humidity a 0-10V or 4-20mA voltage or current output. Scaling tables are available for all of the above-mentioned thermocouples.
Overview of the different end connections of the probe thermocouples:
Overview of the different cable types:

PVC – up to 105°C

silicone – up to180°C

high-temperature silicone – up to 260°C

glass wool – up to 400°C
Product number – Temperature Probe (general product family)
Product number: ANDKBTF
Technical Specification – Temperature Probe KBTF
Operating temperature:: | See table above (105°C / 180 °C / 260 °C / 400 °C) |
Thermocouple: | |
Switching type: | 2-wire (standard) / 3-wire / 4-wire |
Connection: | Core-end sleeves |
Additional mounting equipment: | Immersions sleeves |
Connecting cable: | 2 m (any length according to customer’s needs – extra charge) |
Installation length: | 6x50mm |
Probe diameter: | Ø 3mm (optional Ø 4mm, Ø 5mm, Ø 6mm …) |
Mechanical protection: | IP65 – standard for PVC, Silicone, HT-Silicone cables IP54 – for glass wool cables IP68 (optional) – watertight rubber moulded |
Different temperature probe outputs
Other versions:
Active Temperature Probe ANDKBTF/MU,
Modbus Temperature Probe ANDKBTF/MD.
Datasheet ANDKBTF
Versions of ANDKBTF temperature probe
Type of thermocouple | PVC up to 105°C | Silicone up to 180°C | Silivone HT up to 250°C | Glass Fibre up to 400°C |
PT100 | yes | yes | yes | yes |
PT100 1/3DIN | yes | yes | yes | no |
PT1000 | yes | yes | yes | yes |
PT1000 1/3DIN | yes | yes | yes | no |
Ni1000 | yes | yes | yes | no |
Ni1000TK5000 | yes | yes | yes | no |
NTC 5k, 10k, 20k, Precon, KTY81-210 | yes | yes | yes | no |
NTC 1,8kOhm | yes | yes | yes | no |
LM235Z | yes | yes | yes | no |
DS18B20 | yes | yes | yes | no |
How do we order?
Example: probe ANDKBTF with thermocouple type Ni1000 with silicone HT = ANDKBTF / Ni1000 / Silicone HT
Similar products
Immersion sleeves
If you need immersion sleeves for the sensor, you can see them on the following link: Immersion sleeves