Electrical connections are the backbone of Andivi’s BACnet Multi Sensor operation within a building automation system (BAS). These BACnet Sensors —used to monitor temperature, humidity, CO2, occupancy, and more—rely on precise wiring to power their internal components and transmit data to the BAS. Whether using BACnet MSTP (RS-485) or BACnet IP protocols, the electrical setup determines whether the sensor functions as intended. Here’s why it’s so critical and why accuracy in execution matters:
Electrical Connection in BACnet Sensor
- Definition: This refers specifically to the process or method of linking the sensor to an electrical circuit or system so it can receive power and transmit signals.
- Focus: It involves the wiring, terminals, connectors, and electrical interfaces (e.g., voltage, current, or data lines like I2C, SPI, or analog signals).
- Details:
- Connecting the sensor’s power supply (e.g., positive and ground wires).
- Attaching signal output lines (e.g., to a microcontroller, PLC, or data logger).
- Ensuring proper polarity, voltage levels, and compatibility with the system.
- May involve soldering, crimping, or using connectors like screw terminals or plugs.


Pin Connections
Pin
A pin is a metal connector on a device or cable that facilitates electrical connections. Each pin is designed to serve a specific function, such as power supply, communication, or grounding.
+Vin / ~Vin
- +Vin: This stands for Positive Voltage Input. It is the pin where the positive wire from the power supply is connected to deliver power to the device.
- ~Vin: The tilde (~) symbol indicates that this pin can accept both alternating current (AC) and direct current (DC) voltage inputs. Always verify the device’s specifications to ensure compatibility with the intended power source.
-Vin / ~Vin
- -Vin: This stands for Negative Voltage Input. It is the pin where the negative wire from the power supply is connected to complete the electrical circuit.
- ~Vin: Similar to the positive pin, the tilde (~) indicates that this pin can also handle AC voltage input in addition to DC.

Why Correct Electrical Connections Matter for BACnet Sensors
Drives the Sensor’s Functionality
BACnet sensors require a stable power supply (typically 24V AC/DC) to operate their sensing elements, microprocessors, and communication modules. The electrical connection—via pins like +Vin (positive voltage input) and -Vin (negative voltage input)—delivers this energy.
Why does it matter?
- Polarity: In DC setups, reversing +Vin and -Vin can prevent the sensor from powering on or damage its circuitry. For example, a 24V sensor wired backwards might burn out sensitive components.
- Voltage Match: Supplying incorrect voltage (e.g., 30V to a 24V sensor) can overload and destroy it, while undervoltage (e.g., 18V) may cause erratic operation or failure to boot.
- Impact: Without proper power, the sensor is a dead device, rendering the BAS blind to environmental conditions.
Enables Communication with the BAS
BACnet sensors transmit data (e.g., temperature readings) to the BAS for real-time monitoring and control. Electrical connections facilitate this via:
- MSTP (RS-485): Data lines (e.g., BACnet + and -) connect the sensor to the network.
- IP: An Ethernet cable links the sensor to the IP network.
Why does it matter?
- Wiring Accuracy: For MSTP, swapping BACnet + and – lines disrupts communication, as RS-485 relies on differential signaling. In IP setups, a loose Ethernet connection halts data flow.
- Termination: In MSTP networks, omitting 120-ohm termination resistors at the ends causes signal reflections, leading to data errors or network dropouts, especially over long cable runs (e.g., >1,000 meters).
Ensures Data Accuracy and Reliability
The electrical connection affects the sensor’s ability to produce consistent, accurate readings. Power fluctuations or noise in communication lines can distort the sensor’s output.
Why does it matter?
- Stable Power: Voltage drops or surges (e.g., from a poorly regulated supply) can cause the sensor to misread conditions—say, reporting 25°C when it’s 22°C—leading to incorrect BAS responses.
- Clean Signals: EMI from sloppy wiring (e.g., unshielded cables near motors) can corrupt data, making a CO2 sensor report 800 ppm instead of 400 ppm, triggering unnecessary ventilation.
Prevents System Failures and Downtime
BACnet sensors are often part of a larger network controlling critical building systems (e.g., HVAC, lighting). A single faulty connection can cascade, affecting the entire BAS.
Why does it matter?
- Short Circuits: Loose or exposed wires can short, tripping the power supply or damaging the sensor and nearby devices.
- Network Disruption: In MSTP, one miswired sensor can flood the network with errors, slowing communication for all devices.
- Durability: Overloaded connections (e.g., from overvoltage) shorten the sensor’s lifespan, leading to frequent replacements.
Other Key Aspects of Commissioning a Sensor
Mounting
To ensure accurate performance, mount a Temperature Humidity CO2 VOC Sensor at 1.5 meters high in a location free from direct airflow, align the back plate with the “UP” marking, and connect the Modbus or BACnet wiring (pins 3, 4, and 5) for reliable integration with the Building Automation System.
Installation
Installation integrates the BACnet sensor into its environment with proper mounting, wiring, and network compatibility, avoiding issues like poor cable planning or exceeding its 0-50°C range through a test-fit.
Setup
Testing